400-8006-805
Items | Instructions |
Cabinet Installation Standards | 21-inch ETSI-compliant width 19-inch IEC-compliant width |
Dimensions (W × D × H, excluding packing material) | 442mm × 220mm × 132.6mm |
Dimensions (W × D × H, including packing material) | 585mm × 390mm × 360mm |
Chassis Height | 3U |
MTBF | 112.71 year |
MTTR | 0.5 hour |
Availability | 0.999999494 |
Power Supply System | AC |
Rated Input Voltage | 200V to 240V/100V to 127V dual live wire with 240V HVDC support |
Input Voltage Range | 90V to 290V |
Maximum Input Current | 10A |
Rated Output Power | 1500W |
Maximum Input Line Diameter [mm²] | C13 cable as standard |
Front Stage Circuit Breaker/Fuse | ≥10A |
Heat Dissipation Method | System air cooling |
Air Flow Direction | Left in and right out |
Room Temperature Noise (sound power) | <72dB (meets ETSI 72dBA) |
100GE Maximum Number of ports | IPUA-1T2/IPUA-1T2-B:9; IPUA-480/IPUA-480-B:4 |
50GE Maximum Number of Ports | IPUA-1T2/IPUA-1T2-B:12; IPUA-480/IPUA-480-B:8 |
40GE Maximum Number of Ports | IPUA-1T2/IPUA-1T2-B:9; IPUA-480/IPUA-480-B:4 |
25GE Maximum Number of Ports | IPUA-1T2/IPUA-1T2-B:24; IPUA-480/IPUA-480-B:16 |
10GE Maximum number of Ports | IPUA-1T2/IPUA-1T2-B:60; IPUA-480/IPUA-480-B:48 |
Maximum Number of GE Ports | IPUA-1T2/IPUA-1T2-B:120; IPUA-480/IPUA-480-B:120 |
Maximum Number of FE Ports | IPUA-1T2/IPUA-1T2-B:120; IPUA-480/IPUA-480-B:120 |
Maximum Number of Ports of Electrical Port | IPUA-1T2/IPUA-1T2-B:60; IPUA-480/IPUA-480-B:60 |
IPU Redundancy | 1:01 |
Power Supply Redundancy | 1+1 |
Fan Redundancy | 1+1, short-term normal operation in 40℃ environment after single fan failure (2 fans in one fan module) |
Long-term Operating Temperature | -20℃ to 55℃ |
Operating Environment Temperature Change Limit | ≤30℃/hour |
Storage Temperature | -40℃ to 70℃ |
Long-term Working Environment Relative Humidity | 5% to 85%RH, non-condensing |
Short-term Working Environment Relative Humidity | 5% to 95%RH, non-condensing |
Store Relative Humidity | 5% to 95%RH, non-condensing |
Long-term Working Altitude | ≤4000m (when the altitude is between 1800 m and 4000 m, the operating temperature of the equipment will be reduced by 1℃ for every 220 m increase) |
Storage Altitude | <5000m |