400-8006-805
Items | Instructions |
Cabinet installation standards | 21-inch ETSI-compliant width 19-inch IEC-compliant width |
Dimensions (W × D × H, excluding packaging materials) | 442mm × 220mm × 222mm |
Dimensions (W × D × H, including packing material) | 590mm × 390mm × 505mm |
Chassis Height | 5U |
MTBF | 147.34 |
MTTR | 0.5 hour |
Availability | 0.999999613 |
Power Supply System | AC |
Rated Input Voltage | 200V to 240V/100V to 127V dual live wire with 240V HVDC support |
Input Voltage Range | 90V to 290V |
Maximum Input Current | 10A |
Rated Output Power | 2500W |
Maximum Input Wire Diameter [mm²] | C13 cable as standard |
Front Stage Circuit Breaker/Fuse [A] | ≥10A |
Heat Dissipation Method | System air cooling |
Air Flow Direction | Left in and right out |
Room Temperature Noise (sound power) | <72dB (meets ETSI 72dBA) |
Total Slots | 17 |
Number of SPU Slots | 10/12/14 |
Maximum Number of Physical Ports on the Device | 200 |
100GE Maximum Number of Ports | IPUA-2T/IPUA-2T-B:16 IPUA-1T2/IPUA-1T2-B:12 |
50GE Maximum Number of Ports | IPUA-2T/IPUA-2T-B:20 IPUA-1T2/IPUA-1T2-B:20 |
40GE Maximum number of Ports | IPUA-2T/IPUA-2T-B:16 IPUA-1T2/IPUA-1T2-B:12 |
25GE Maximum Number of Ports | IPUA-2T/IPUA-2T-B:64 IPUA-1T2/IPUA-1T2-B:48 |
10GE Maximum Number of Ports | IPUA-2T/IPUA-2T-B:100 IPUA-1T2/IPUA-1T2-B:100 |
Maximum Number of GE Ports | IPUA-2T/IPUA-2T-B:200 IPUA-1T2/IPUA-1T2-B:200 |
Maximum Number of FE Ports | IPUA-2T/IPUA-2T-B:200 IPUA-1T2/IPUA-1T2-B:200 |
Maximum Number of Ports of Electrical Port | IPUA-2T/IPUA-2T-B:100 IPUA-1T2/IPUA-1T2-B:100 |
IPU Redundancy | 1:1 |
Power Supply Redundancy | 2+2 |
Fan Redundancy | 3+1: Short-term normal operation at 40℃ after a single fan fails (One fan module contains four fans) |
Long-term Operating Temperature | -20℃ to 55℃, starting: ≥-5 ℃ |
Operating Environment Temperature Change Limit | ≤ 30℃/hour |
Storage Temperature | -40℃ to 70℃ |
Long-term Working Environment Relative Humidity | 5% to 85% RH, non-condensing |
Short-term Working Environment Relative Humidity | 5% to 95% RH, non-condensing |
Store Relative Humidity | 5% to 95% RH, non-condensing |
Long-term Working Altitude | ≤4000m (When the altitude is between 1800 m and 4000 m, each rise of 220 m, equipment transport Row temperature is reduced by 1℃) |
Storage Altitude | < 5000m |