400-8006-805
Model Number | OceanStor 5310-G | OceanStor 5510-G |
Hardware Specifications | ||
Dual-control Cache | 128 GB to 256 GB | 256 GB to 2048 GB |
Maximum Available Capacity/Controller Enclosure | 2.5*PiB | 16*PiB |
Supported Storage Protocol | FC, iSCSI, FC-NVMe , NVMe over RoCE , NFS, CIFS, NDMP, NFS over RDMA | FC, iSCSI, FC-NVMe, NVMe over RoCE, NFS, CIFS, NDMP, NFS over RDMA, S3* |
Front-end Channel Port Type | 8/16/32 Gbit/s FC/FC-NVMe, 10/25/40/100 GbE, 25 Gb NVMe over RoCE/NFS over RDMA | |
Type of Back-end Channel Port | 100G RDMA | |
Maximum Number of Hot-swappable I/O Modules/Controller Enclosures | 6 | 12 |
Maximum Number of Front-end Host Ports/Controller Enclosures | 40 | 48 |
Type of Hard Disk | 15.36/30.72 TB palm-sized Capacity NVMe SSD | |
Software Specifications | ||
RAID Support | RAID 10*, RAID 5, RAID 6, RAID-TP (tolerance for simultaneous failure of 3 disks) | |
Electrical Specifications | ||
Power Source | 200V to 240VAC±10%, 192V to 288VDC | |
Dimensions (H × W × D) | Control box: 86.1mm × 447mm × 620mm | Controller box: 86.1mm × 447mm × 920mm |
Smart NVMe disk enclosure: 86.1mm × 447mm × 620mm | ||
NVMe controller enclosure ≤ 32kg Intelligent NVMe disk enclosure ≤ 35kg | NVMe controller ≤ 50kg Intelligent NVMe disk enclosure ≤ 35kg | |
Operating Ambient Temperature | The ambient temperature when the altitude is -60 to +1800m is 5℃ to 35℃ (cabinet) /40℃ (frame) | |
When the altitude is from 1800m to 3000m, the ambient temperature (upper limit) is reduced by 1℃ for every 220m increase in altitude | ||
Working Environment Humidity | 10% to 90% RH |